Stability: local or ref
For the critical cut length (and possibly other parameters), it would be useful to be able to decide if we evaluate on the local slope or on a reference slope (38 deg). A new key should allow to configure this behavior (useful for Alpine3D for example).
Moreover, in the computation of the critical cut length (and others), we should make sure that we don't produce arithmetic exceptions in this case...